| Input Power |
|
| |
Voltage |
: 200 V ac rms +/- 10% |
| |
Frequency |
: 400 Hz |
| Output Power |
|
| |
Voltage |
: 80 V dc at 200 V a.c. input |
| |
Current |
: 6 Amps dc, 8 Amps for 10 secs for motor starting. |
| Field Resistance |
: 10 ohms, minimum |
| Build up |
: Less than 5V a.c. rms at VCU power input terminals. |
| Regulation |
: +/- 1% of set voltage |
| Voltage Adjustment |
: +/- 10% over 200V |
| Stability Adjustment |
: Adjustable to get stable operation and desired response. |
| Voltage Sensing |
: |
200 V a.c. two line sensing. VCU senses average of the generator wave form. |
| Response time |
: Less than75 milli seconds. |
| Under frequency Protection (FRO) |
: Adjustable from 350Hz to 450Hz. |
| Circuit Protection |
: |
Protection against voltage transients by L-C networks and high energy suppressors. |
| RFI Suppression |
: |
VCU includes RFI filters to filter out the RFI generated due to power device turn on. |
| Temperature drift |
: |
Typically 0.025% per degree celcius over operating temperature range. |
| Fuse |
: 4 amps fuse provided inside the VCU box. |
| Operating temperature |
: -20 degree celcius to + 60 degree celcius ambient. |
| Power dessipation |
: 10 watts (max) |
| Size (LBH) |
: AX03 : 150x140x40 |
| Weight |
: AX03 : 765 gms |